Menü überspringen

LF 185

Specifications

LF 185

Measuring standard

Coefficient of linear expansion

SUPRADUR phase grating on steel, grating period 8 µm

αtherm ≈  10 x 10-6 K-1

Accuracy grade*

± 3 µm; ± 2 µm

Measuring length ML*
in mm

140, 240, 340, 440, 540, 640, 740, 840, 940, 1040, 1140, 1240

(greater measuring lengths in preparation)

Incremental signals

1 VPP

Signal period

4 µm

Reference marks* LF 185
LF 185 C

One reference mark at midpoint; other reference mark positions upon request

Distance-coded

Cutoff frequency –3 dB

≥ 250 kHz

Electrical connection

Separate adapter cable (1 m/3 m/6 m/9 m) connectable to mounting block

Cable length

≤ 150 m (with HEIDENHAIN cable)

Power supply without load

5 V DC ± 5 %/< 120 mA

Traversing speed

≤ 60 m/min

Required moving force

≤ 4 N

Vibration 55 Hz to 2 000 Hz
affecting the

Shock 11 ms

Acceleration

Housing: ≤ 150 m/s2 (EN 60 068-2-6)

Scanning unit: ≤ 200 m/s2 (EN 60 068-2-6)

≤ 300 m/s2 (EN 60 068-2-27)

≤ 100 m/s2 in measuring direction

Operating temperature

0 °C to 50 °C

Protection EN 60 529

IP 53 when installed according to instructions in the brochure

IP 64 with sealing air via DA 400

Weight

0.8 kg + 4.6 kg/m measuring length

* Please select when ordering