Menü überspringen

LC 195

Specifications

LC 195 F

LC 195 M

LC 195 S

Measuring standard

Coefficient of linear expansion

DIADUR glass scale with absolute track and incremental track, grating period 20 µm

αtherm ≈  8 x 10-6 K-1

Accuracy grade*

± 3 µm up to measuring length 3 040 mm; ± 5 µm

Measuring length ML*
in mm

140, 240, 340, 440, 540, 640, 740, 840, 940, 1040, 1140, 1240, 1340, 1440,

1540, 1640, 1740, 1840, 2040, 2240, 2440, 2640, 2840, 3040, 3240, 3440, 3640, 3840,

4040, 4240

Functional safety*

Option1)

Interface

Fanuc Serial Interface Þi interface

Mitsubishi high speed interface

DRIVE-CLiQ

Ordering designation

Fanuc05

Mit03-04

DQ01

Resolution

At ± 3 µm

At ± 5 µm

Þi interface/Þ interface

0.00125 µm/0.010 µm

0.0125 µm/0.050 µm

0.001 µm

0.010 µm

Diagnostics interface

Digital

Electrical connection

Separate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting block

Cable length

≤ 50 m

≤ 30 m

≤ 30 m2)

Voltage supply

3.6 V to 14 V DC

10 V to 28.8 V DC

Power consumption (max.)

3.6 V: ≤ 1.1 W; 14 V: ≤ 1.3 W

10 V: ≤ 1.5 W; 28.8 V: ≤ 1.7 W

Current consumption (typical)

5 V: 140 mA (without load)

24 V: 46 mA (without load)

Traversing speed

≤ 180 m/min

Required moving force

≤ 4 N

Vibration 55 to 2 000 Hz
affecting the

Shock 11 ms

Acceleration

Housing: ≤ 200 m/s2 (EN 60 068-2-6)

Scanning unit: ≤ 200 m/s2 (EN 60 068-2-6)

≤ 300 m/s2 (EN 60 068-2-27)

≤ 100 m/s2 in measuring direction

Operating temperature

0 °C to +50 °C

Protection EN 60 529

IP 53 when installed according to instructions in the brochure, IP 64 with sealing air from DA 400

Weight

0.55 kg + 2.9 kg/m measuring length

* Please select when ordering

1) For dimensions and specifications, see separate Product Information document

2) Greater cable lengths in preparation