Menü überspringen

ERO 6000 series

Request

Scanning head

AK ERO 6080

AK ERO 6070

Interface

1 VPP

TTL x 5

TTL x 10

TTL x 50

Reference mark signal

Square-wave pulse

Integrated interpolation*

5-fold

10-fold

50-fold

Cutoff frequency –3 dB

200 kHz

Scanning frequency

200 kHz

100 kHz

25 kHz

Edge separation a

0.220 µs

0.220 µs

0.175 µs

Electrical connection

Cable 3 m with male D-sub connector (15-pin), interface electronics for ERO 6070 in the connector

Cable length

30 m

Voltage supply

5 V DC ± 0.25 V

Current requirement

< 100 mA (without load)

< 200 mA (without load)

Vibration 55 to 2 000 Hz

Shock 6 ms

200 m/s2 (EN 60 068-2-6)

500 m/s2 (EN 60 068-2-27)

Operating temperature

0 °C to 50 °C

Weight Scanning head

(approx.) Connector

Cable

6 g (without cable)

32 g

22 g/m

6 g (without cable)

140 g

22 g/m

Graduated disk

TKN ERO 6000

Measuring standard

METALLUR graduation on glass

Signal periods*

9 000

18 000

Accuracy of graduation

± 5”

± 3,5”

Position error per signal period1)

± 2”

± 1”

Reference marks

One

Hub inside diameter

25 mm

95 mm

Circular scale outside diameter

71 mm

150 mm

Mech. permissible speed

1 600 min-1

800 min-1

Moment of inertia

44 x 10-6 kgm2

1.1 x 10-3 kgm2

Permissible axial motion

0.1 mm

Protection EN 60 529

IP 00

Weight (approx.)

84 g

323 g

* Please select when ordering

1) The position error within one signal period and the accuracy of the graduation result together in the encoder-specific error; for additional error through mounting and the bearing of the measured shaft, see Measuring accuracy